Getting such information is not generally as easy as just getting a location curve.
Curved column line revit not seen on other floors.
Doubly curved surfaces generated by slab shape points are not supported.
This is related to the auto detect settings for the column s analytical model and also the tolerances set in structural settings.
Verify that the element is not hidden by a masking region or a filled region.
When you tried to underlay a floor only doors and windows were visible.
First post here and i hope i am in the right place.
Ami out of luck or is there some trick i don t know yet.
If the view range intersects the geometry of a level in your main view that level cannot be used as an underlay in the main view.
For vertical columns you can derive end points via level parameters and offsets.
Is your grids workset opened in the project.
In plan view click view menu view properties.
In the main floor level the bottom of the primary range is set to main floor with an offset of 1.
See masking regions and filled regions.
If you see the missing grid select it right click and choose unhide in view.
If not apologies in advance.
Ensure the link is visible in the view.
Konstru will store split lines and slab shape points but represent the floor outline only.
Ensure the link is loaded.
Structural analytical lines are not centered on columns when grade beams are off center.
Those floors will be ignored entirely.
I am trying to create a gap in a curved grid line but this seems beyond revit s capabilities.
It follows the below procedure.
To prevent the floor or slab from being visible in plan view you need to adjust the bottom clip so that it is more than 4 feet above the floor or slab and set the view depth so that it does not include any part of the floor or slab.
Thank you all kindly.
To see if this is the problem toggle on the reveal hidden elements tool.
Verify that your grids workset display yes in the opened column.
See override individual lines in an element.
See unload and reload linked models.
To check click the worksets icon in the collaborate tab.
An even more bizarre example is where a revit floor will disregard your view depth and show anyway as long as it is within an arbitrarily picked range of 4 feet of your bottom clip.
A slanted column on the other hand is equipped with a location curve.
The application is working as expected and as designed however a setting change will address this.
If your model in place intersects the cut plane at even just one point it ll show the entire model regardless of whether or not the other parts should be seen.